Vickers D08 Solenoid Valve
Item #101907074
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-356887
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Design No. 10
Solenoid Energization Code None
Seal Material Buna-N
Manual Override Plain Override
Actuator Type Solenoid
Pressure Port Check Valve Code None
Spool Indicator Switch Code None
Crossover All Ports Blocked
Spool Spring Arrangement Code C
Electrical Connection No Connector
Function 3-Position Spring Centered
Pressure [Max] 5000 psi
Port T Pressure Rating 5000 psi
Mechanical Options Code None
EN Code None
Electrical Options Code None
Surge Suppressor/Damper None
Reducer Module N/A
Overrides Plain Override Solenoid Ends
Spool Code 2
Center Position All Ports Blocked
Surge Suppressor/Damper Code None
Pilot Pressure Code E
Response Type Code X
Indicator Lights No
Tank Port Rating 5000
AC/DC AC
Pilot Valve Type Code H
Housing Code None
Coil Rating Code B
Pilot/Drain External Pilot/Internal Drain
Mechanical Options None
Port Restrictor Plug Code None
Coil Type DIN 43650
Electrical Connector Code None
Operation Pilot Operated
Electrical Options None
Rated Flow [Max] 185 gal/min
Pilot Valve Type CETOP 3, High Performance
Valve Type Standard-Duty
Pressure Port Check Valve Pressure N/A
Voltage & Frequency 110/120 VAC - 50/60 Hz
Response Type Fast Response
Solenoid Double
NFPA Size D08
Reducer Module Code None
Manual Override Option Code None
Port Restrictor Plugs None
Gauge Port SAE-4
Pilot Drain Code T
Gauge Ports Code None
Spool Control Modification Code None
Model No. DG5V-8-H-2C-X-E-T-M-U-B-10
Coil Type Code U
Solenoid Indicator Lights Code None
Weight 35.0 LB