Vickers by Danfoss02-356887

02-356887

Vickers D08 Solenoid Valve
Item #101907074
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-356887
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Response Type Fast Response
Pressure Port Check Valve Code None
Actuator Type Solenoid
Coil Rating Code B
Manual Override Option Code None
Response Type Code X
Spool Control Modification Code None
Tank Port Rating 5000
AC/DC AC
Mechanical Options None
Pressure [Max] 5000 psi
Pilot Drain Code T
Electrical Options None
Port T Pressure Rating 5000 psi
Spool Spring Arrangement Code C
Operation Pilot Operated
Pilot/Drain External Pilot/Internal Drain
Seal Material Buna-N
Electrical Options Code None
Manual Override Plain Override
Electrical Connection No Connector
Housing Code None
Overrides Plain Override Solenoid Ends
Rated Flow [Max] 185 gal/min
Pressure Port Check Valve Pressure N/A
Function 3-Position Spring Centered
Electrical Connector Code None
Valve Type Standard-Duty
Solenoid Indicator Lights Code None
Center Position All Ports Blocked
Solenoid Double
Crossover All Ports Blocked
Design No. 10
Spool Code 2
Pilot Valve Type CETOP 3, High Performance
Gauge Port SAE-4
Pilot Pressure Code E
Solenoid Energization Code None
Indicator Lights No
Voltage & Frequency 110/120 VAC - 50/60 Hz
Mechanical Options Code None
Surge Suppressor/Damper None
NFPA Size D08
Reducer Module Code None
Spool Indicator Switch Code None
Coil Type DIN 43650
Surge Suppressor/Damper Code None
Gauge Ports Code None
Port Restrictor Plugs None
Reducer Module N/A
Coil Type Code U
Port Restrictor Plug Code None
EN Code None
Model No. DG5V-8-H-2C-X-E-T-M-U-B-10
Pilot Valve Type Code H
Weight 35.0 LB