- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Spool Indicator Switch Code | None |
| Body Material | Ductile Iron |
| Spool Code | 6 |
| Spool Spring Arrangement Code | C |
| Solenoid Energization Code | None |
| Temperature Range [Min] | -40 °F |
| Overrides | Plain Override Solenoid Ends |
| Manual Override | Plain Override |
| Mechanical Options | Adjust Pilot Chokes on Both Ends |
| Solenoid Indicator Lights Code | None |
| Coil Type | ISO 4400 (Din 43650) Connector |
| Response Type | Standard Response |
| Indicator Lights | No |
| Reducer Module | No |
| Coil Rating Code | H |
| Housing Code | None |
| Operation | Pilot Operated |
| Surge Suppressor/Damper Code | None |
| Valve Type | Standard-Duty |
| Pilot/Drain | External Pilot/Internal Drain |
| Manual Override Option Code | None |
| Watt Rating | 30 W |
| Port Restrictor Plugs | None |
| Pressure [Max] | 5000 psi |
| Port Restrictor Plug Code | None |
| AC/DC | DC |
| Seal Material | Buna-N |
| Pilot Pressure Code | None |
| Spool Control Modification Code | 2 |
| Pressure Port Check Valve Code | None |
| Electrical Options | None |
| Fluid Cleanliness | 19/17/14 micron |
| Reducer Module Code | None |
| Solenoid | Double |
| Pilot Valve Type Code | H |
| Leakage | High Performance |
| Actuation Identification | Solenoid A, Solenoid B |
| Rated Flow [Max] | 175 gal/min |
| EN Code | None |
| Model No. | DG5V-8-H-6C-2-T-M-U-H-10 |
| Electrical Options Code | None |
| Performance | High Performance |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Actuator Type | Solenoid |
| Pilot Drain Code | T |
| Response Type Code | None |
| Pilot Valve Type | CETOP 3, High Performance |
| Port T Pressure Rating | 5000 psi |
| Temperature Range [Max] | 230 °F |
| Voltage & Frequency | 24 VDC |
| Tank Port Rating | 5000 |
| Electrical Connector Code | None |
| Mechanical Options Code | None |
| NFPA Size | D08 |
| Function | 3-Position Spring Centered |
| Design No. | 10 |
| Coil Type Code | U |
| Gauge Port | SAE-4 |
| Center Position | P Blocked, A & B to T |
| Pressure Port Check Valve Pressure | N/A |
| Electrical Connection | No Connector |
| Surge Suppressor/Damper | None |
| Mounting | Subplate/Manifold Mount |
| Gauge Ports Code | None |
| No. of Stages | Two Stage |
| Compatible Fluids | Petroleum Oil |
| Crossover | P Blocked, A or B to T |
| Weight | 35.0 LB |