- Solenoid Actuated Valve
- Solenoid Operated Operation
- D05 NFPA Size
- Single Solenoid
- 2-Position Spring Offset Function
description
- DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
- Port connections are made by mounting the valve on a manifold or subplate containing the interface.
- Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.
caution
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Mechanical Options | Single Solenoid Reverse Assembly |
| Flow Direction Code | 4 |
| Actuator Type | Solenoid |
| Spool Center Condition | B Port End |
| Actuation Identification | Solenoid B |
| Center Position | All Ports Blocked |
| Valve Type | Standard-Duty |
| Spool Code | 2 |
| Electrical Connection | Ground Terminal |
| Model No. | DG4S4-012A-50-LH |
| Voltage & Frequency | 115 VAC - 60 Hz |
| Cycle Rate [Max] | N/A |
| Mechanical Options Code | LH |
| Port Restrictor Plugs | None |
| Coil Type | No Coil |
| Crossover | All Ports Blocked |
| Rated Flow [Max] | 20 gal/min |
| Reducer Module | No |
| Solenoid | Single |
| Body Material | Gray Iron |
| Indicator Lights | No |
| Leakage | Standard Performance |
| Design No. | 50 |
| Pressure Port Check Valve Pressure | N/A |
| No. of Stages | Single Stage |
| Solenoid Air Gap Code | None |
| Temperature Range [Min] | 68 °F |
| AC/DC | AC |
| Function | 2-Position Spring Offset |
| Port T Pressure Rating | 1000 psi |
| Surge Suppressor/Damper | None |
| Pressure [Max] | 3600 psi |
| Response Type | Standard Response |
| Spool Spring Arrangement Code | A |
| Pilot/Drain | None |
| Temperature Range [Max] | 179.6 °F |
| Tank Port Rating | 1000 |
| Overrides | No Overrides |
| Seal Material | Buna-N |
| Pilot Valve Type | N/A |
| NFPA Size | D05 |
| Mounting | Subplate/Manifold Mount |
| Fluid Cleanliness | 19/17/14 micron |
| Electrical Options | None |
| Operation | Solenoid Operated |
| Electrical Options Code | None |
| Coil Rating Code | None |
| Weight | 1.0 LB |