  • Pressure Control Valve
  • Pressure Relief Valve Type
  • RV5-10 Series
  • Cartridge Only Port Size
  • Cartridge Only Port Type
  • Pilot Operated Operation
+ Show More + Show Less
Vickers by Danfoss889560
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Pressure Control Valve
  • Pressure Relief Valve Type
  • RV5-10 Series
  • Cartridge Only Port Size
  • Cartridge Only Port Type

caution

  • Steel housings must be used for operating pressures above 3,000 psi
Style Spool
Seal Kit Viton 566086
Type Pressure Relief Valve
Flow [Max] 30 gal/min
Temperature Range [Max] 248 °F
No. of Housing Ports 2
Seal Kit Buna 565803
Valve Material Cartridge only
Cavity C-10-2
Housing Material Cartridge Only
Series RV5-10
Manufacturer Part No. RV5-10-F-0-50/
Seal Material Buna-N
Pressure [Max] 3452 psi
Installation Screw-in Cartridge
Operating Pressure [Max] 5076 psi
Pilot Ratio 100:1
Operation Pilot Operated
Cracking Pressure [Max] 5000 psi
Model No. RV5-10-F-0-50/
Leakage 114 cc/min
Pressure Setting 2792 psi
Cage Seals Single Backup Ring
Cracking Pressure [Min] 500 psi
Recommend Filtration Level 18/16/13 microns
No. of Valve Ports 2
Adjustment Type Fixed - State Pressure Setting Required
Port Size Cartridge Only
Operating Pressure [Min] 508 psi
Temperature Range [Min] -40 °F
Port Type Cartridge Only
Weight 0.48 LB