caution

  • Steel housings must be used for operating pressures above 3,000 psi
Type Pressure Relief Valve
Housing Material Cartridge Only
Temperature Range [Max] 248 °F
Recommend Filtration Level 18/16/13 microns
Series RV5-10
Valve Material Cartridge only
Port Size Cartridge Only
Operating Pressure [Max] 5076 psi
Pressure [Max] 3452 psi
No. of Valve Ports 2
Seal Kit Buna 565803
Style Spool
Flow [Max] 30 gal/min
Manufacturer Part No. RV5-10-F-0-50/
Installation Screw-in Cartridge
Cavity C-10-2
Model No. RV5-10-F-0-50/
Cracking Pressure [Min] 500 psi
No. of Housing Ports 2
Operating Pressure [Min] 508 psi
Operation Pilot Operated
Cracking Pressure [Max] 5000 psi
Seal Material Buna-N
Cage Seals Single Backup Ring
Port Type Cartridge Only
Leakage 114 cc/min
Pilot Ratio 100:1
Adjustment Type Fixed - State Pressure Setting Required
Pressure Setting 2792 psi
Temperature Range [Min] -40 °F
Seal Kit Viton 566086
Weight 0.48 LB