Vickers D03 Solenoid Valve

02-146885

Vickers D03 Solenoid Valve
Item #102086782
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Port T Pressure Rating 3000 psi
Function 3-Position Spring Centered
Pressure Port Check Valve Pressure N/A
Pressure [Max] 5000 psi
Housing Code W
Electrical Options None
Mounting Subplate/Manifold Mount
Watt Rating 30 W
Coil Rating Code H
Port Restrictor Plugs None
Temperature Range [Min] -4 °F
Body Material Gray Iron
Port Restrictor Plug Code None
Manual Override Plain Override
Crossover P Blocked, A or B to T
Seal Material Buna-N
Solenoid Indicator Lights Code L
Electrical Connector Code PA5
Compatible Fluids Petroleum Oil
Spool Spring Arrangement Code C
Function Code 6
Reducer Module No
Performance High Performance
Center Position P Blocked, A & B to T
Cycle Rate [Max] N/A
Solenoid Code H
NFPA Size D03
Operation Solenoid Operated
Surge Suppressor/Damper None
Response Type Standard Response
Tank Port Rating 3046
Pilot/Drain None
Temperature Range [Max] 158 °F
Solenoid Double
AC/DC DC
Valve Type High-Performance
Model No. DG4V 3 6C M FPA5WL H7 60
Fluid Cleanliness 19/17/14 micron
No. of Stages Single Stage
Surge Suppressor/Damper Code None
Electrical Connection Five Pin Connector
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Manual Override Option Code None
Port T Code 7
Solenoid Energization Code None
Voltage & Frequency 24 VDC
Design No. 60
Spool Shift Timing N/A
Spool Indicator Switch Code None
Leakage Standard Performance
Pilot Valve Type N/A
Coil Type Code F
Mechanical Options None
Rated Flow [Max] 20 gal/min
Response Time 28 to 45 ms
EN Code None
Spool Code 6
Indicator Lights Yes
Actuation Identification Solenoid A, Solenoid B
Actuator Type Solenoid
Overrides No Overrides
Weight 5.0 LB