Vickers D03 Solenoid Valve

02-146885

Vickers D03 Solenoid Valve
Item #102086782
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Spool Indicator Switch Code None
Mechanical Options None
Indicator Lights Yes
Model No. DG4V 3 6C M FPA5WL H7 60
Body Material Gray Iron
Coil Rating Code H
Seal Material Buna-N
Surge Suppressor/Damper Code None
Pilot/Drain None
Electrical Connection Five Pin Connector
Surge Suppressor/Damper None
No. of Stages Single Stage
Tank Port Rating 3046
Temperature Range [Min] -4 °F
Manual Override Option Code None
Spool Spring Arrangement Code C
Valve Type High-Performance
Mounting Subplate/Manifold Mount
Performance High Performance
Crossover P Blocked, A or B to T
Watt Rating 30 W
Manual Override Plain Override
Leakage Standard Performance
Solenoid Indicator Lights Code L
Solenoid Double
AC/DC DC
Response Time 28 to 45 ms
Electrical Options None
Spool Code 6
Solenoid Code H
Pressure [Max] 5000 psi
Port Restrictor Plugs None
Pilot Valve Type N/A
Actuation Identification Solenoid A, Solenoid B
Port T Code 7
Port T Pressure Rating 3000 psi
Center Position P Blocked, A & B to T
Coil Type Code F
Port Restrictor Plug Code None
Voltage & Frequency 24 VDC
Solenoid Energization Code None
Reducer Module No
NFPA Size D03
Pressure Port Check Valve Pressure N/A
Temperature Range [Max] 158 °F
Cycle Rate [Max] N/A
Design No. 60
Overrides No Overrides
Housing Code W
Rated Flow [Max] 20 gal/min
Function Code 6
Response Type Standard Response
Spool Shift Timing N/A
Actuator Type Solenoid
Compatible Fluids Petroleum Oil
Operation Solenoid Operated
Function 3-Position Spring Centered
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Connector Code PA5
Fluid Cleanliness 19/17/14 micron
EN Code None
Weight 5.0 LB