- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Overrides | Plain Override Solenoid Ends |
Pressure Port Check Valve Code | None |
Coil Rating Code | H |
Pressure [Max] | 5000 psi |
Pilot Valve Type Code | H |
Seal Material | Buna-N |
Port Restrictor Plug Code | None |
Spool Spring Arrangement Code | C |
Reducer Module | No |
Actuator Type | Solenoid |
Fluid Cleanliness | 19/17/14 micron |
Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
Response Type Code | None |
Response Type | Standard Response |
Manual Override Option Code | None |
Rated Flow [Max] | 175 gal/min |
Pressure Port Check Valve Pressure | N/A |
Mechanical Options | Adjust Pilot Chokes on Both Ends |
Surge Suppressor/Damper Code | None |
Function | 3-Position Spring Centered |
Valve Type | Standard-Duty |
Body Material | Ductile Iron |
Tank Port Rating | 5000 |
Compatible Fluids | Petroleum Oil |
Solenoid Energization Code | None |
Coil Type | ISO 4400 (Din 43650) Connector |
Operation | Pilot Operated |
Mounting | Subplate/Manifold Mount |
Pilot Drain Code | T |
Electrical Options Code | None |
Electrical Options | None |
Housing Code | None |
Spool Control Modification Code | 2 |
Watt Rating | 30 W |
Spool Code | 6 |
Pilot Valve Type | CETOP 3, High Performance |
Pilot Pressure Code | None |
Crossover | P Blocked, A or B to T |
Model No. | DG5V-8-H-6C-2-T-M-U-H-10 |
Temperature Range [Max] | 230 °F |
Port Restrictor Plugs | None |
AC/DC | DC |
Mechanical Options Code | None |
Surge Suppressor/Damper | None |
EN Code | None |
Solenoid Indicator Lights Code | None |
Center Position | P Blocked, A & B to T |
Performance | High Performance |
Reducer Module Code | None |
Electrical Connection | No Connector |
Gauge Ports Code | None |
Gauge Port | SAE-4 |
Design No. | 10 |
Temperature Range [Min] | -40 °F |
Port T Pressure Rating | 5000 psi |
Voltage & Frequency | 24 VDC |
Pilot/Drain | External Pilot/Internal Drain |
Electrical Connector Code | None |
NFPA Size | D08 |
Manual Override | Plain Override |
No. of Stages | Two Stage |
Coil Type Code | U |
Spool Indicator Switch Code | None |
Leakage | High Performance |
Solenoid | Double |
Indicator Lights | No |
Actuation Identification | Solenoid A, Solenoid B |
Weight | 35.0 LB |