- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Compatible Fluids | Petroleum Oil |
| Pilot Valve Type Code | H |
| Surge Suppressor/Damper | None |
| Gauge Port | SAE-4 |
| Performance | High Performance |
| Spool Control Modification Code | None |
| Pilot/Drain | External Pilot/External Drain |
| Solenoid Energization Code | None |
| Mechanical Options | None |
| Reducer Module Code | None |
| Pressure [Max] | 5000 psi |
| Overrides | Plain Override Solenoid Ends |
| Design No. | 10 |
| Valve Type | Standard-Duty |
| Solenoid Indicator Lights Code | None |
| Model No. | DG5V-8-H-6C-E-M-FW-B-10 |
| Pilot Pressure Code | E |
| Fluid Cleanliness | 19/17/14 micron |
| Spool Spring Arrangement Code | C |
| Function | 3-Position Spring Centered |
| Reducer Module | No |
| Crossover | P Blocked, A or B to T |
| Housing Code | W |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Spool Indicator Switch Code | None |
| Body Material | Ductile Iron |
| NFPA Size | D08 |
| Pilot Drain Code | None |
| Mechanical Options Code | None |
| Electrical Connector Code | None |
| Actuator Type | Solenoid |
| Response Type Code | None |
| Indicator Lights | No |
| Coil Type Code | F |
| Port Restrictor Plug Code | None |
| Pressure Port Check Valve Pressure | N/A |
| Spool Code | 6 |
| Surge Suppressor/Damper Code | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Pressure Port Check Valve Code | None |
| Response Type | Standard Response |
| Center Position | P Blocked, A & B to T |
| Port T Pressure Rating | 5000 psi |
| Pilot Valve Type | CETOP 3, High Performance |
| Temperature Range [Min] | -40 °F |
| No. of Stages | Two Stage |
| Port Restrictor Plugs | None |
| Rated Flow [Max] | 175 gal/min |
| Coil Rating Code | B |
| Electrical Connection | No Connector |
| Temperature Range [Max] | 230 °F |
| Leakage | High Performance |
| Electrical Options Code | None |
| Solenoid | Double |
| Seal Material | Buna-N |
| Operation | Pilot Operated |
| EN Code | None |
| Tank Port Rating | 5000 |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Manual Override Option Code | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Gauge Ports Code | None |
| Mounting | Subplate/Manifold Mount |
| AC/DC | AC |
| Manual Override | Plain Override |
| Electrical Options | None |
| Weight | 35.0 LB |