Vickers by Danfoss02-330433

02-330433

Vickers D08 Solenoid Valve
Item #102084205
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-330433
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Spool Code 9
Solenoid Indicator Lights Code L
Electrical Options None
Spool Indicator Switch Code None
Port Restrictor Plug Code None
Gauge Port SAE-4
Housing Code W
Spool Spring Arrangement Code N
Reducer Module Code None
Surge Suppressor/Damper None
Leakage Standard Performance
Pilot Drain Code None
Mechanical Options None
Model No. DG5V-8-S-9N-M-FTWL-B-10
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Port Restrictor Plugs None
Center Position All Ports Open Over Tapers
Fluid Cleanliness 19/17/14 micron
Rated Flow [Max] 175 gal/min
Port T Pressure Rating 5000 psi
Pilot Valve Type Code S
Surge Suppressor/Damper Code None
Response Type Code None
Electrical Options Code None
AC/DC AC
Compatible Fluids Petroleum Oil
EN Code None
Coil Rating Code B
Actuator Type Solenoid
Mounting Subplate/Manifold Mount
NFPA Size D08
Pressure Port Check Valve Pressure N/A
Function 3-Position Detented
Pressure Port Check Valve Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Connection Wired Terminal Block
Pilot Pressure Code None
Crossover All Ports Open
Seal Material Buna-N
Pilot Valve Type CETOP 3, Standard Performance
Performance Standard Performance
Manual Override Option Code None
Body Material Gray Iron
Voltage & Frequency 110/120 VAC - 50/60 Hz
Reducer Module No
Pressure [Max] 5000 psi
Solenoid Double
No. of Stages Two Stage
Spool Center Condition A Port and Double Offset sensing switch on B Port
Electrical Connector Code T
Response Type Standard Response
Solenoid Energization Code None
Operation Pilot Operated
Pilot/Drain External Pilot/Internal Drain
Manual Override Plain Override
Indicator Lights Yes
Gauge Ports Code None
Coil Type Code F
Mechanical Options Code None
Tank Port Rating 5000
Valve Type Standard-Duty
Overrides Plain Override Solenoid Ends
Design No. 10
Spool Control Modification Code None
Weight 35.0 LB